Structural design 1000 a ni.
He furnace hi stainless steel plate a siam a ni a, heating leh hot air circulation chamber hmanga hual vel a ni a, boruak lum chu furnace chhungah a luang a, hei hian temperature uniformity nasa takin a ti tha a ni. Thli lum a hrual avangin furnace chamber chhunga boruak a convection leh soaking effect a tichak a.
Furnace chamber leh furnace frame chu a inthen a, furnace chamber chu load-ah dah a ni-Furnace frame hnuai lamah bearing rollers a awm a, chu chu hma leh hnung lamah zalen takin a tlan thei a ni. Furnace chamber chu a lum chuan a sei zawngin zalen takin a sei thei a ni.
Furnace chamber chhunga gas lum leak lo tur ven nan a vaiin sealing layer 2 vel chu a chhung atanga furnace kawngka pawn lam thlengin an siam a ni. A chhung lam chu ceramic fiber rope hmanga seal a ni a, a pawn lam chu silicone rubber sealing ring hmanga seal a ni a, a service life tih rei theih nan stainless steel cooling water jacket chu furnace muzzle seal-ah design a ni a, a lum leh a lum theih nan a siam a ni. Door lock hian multi-point handwheel rotation locking mechanism a hmang a, chu chuan kawngkhar chu a rualin a lock thei a ni. Chu bakah, furnace chamber tawp lamah furnace door fixture dah a ni a, movable double hinge mechanism a hmang a, chu chu furnace chamber free elongation nen a kal thei a, sealing effect tha zawk a nei bawk.
Thil hmanrua chung lam chu exhaust chimney hmanga siam niin, exhaust gas leh heating process chhunga meikhu siam chhuah a ni a, exhaust flow chu damper handle siamrem hmangin control theih a ni.
Control system design a ni a .
Control system chu furnace body-ah a inzawm khawm a ni. Intelligent program temperature controller chu thlan a ni a, temperature curve siamremna chu automatic control setting hmangin tih a ni. Linear combination hian control quantity a siam a, control object a control bawk. Thermostat hian thermocouple-in signal a hmuh chu a dawng a, power module chu a control a ni.
Fan position design a ni a .
Fan chu furnace hnung lamah a awm a, boruak chu volute leh a sir lehlama boruak duct hmangin heating element hmangin a puak a, boruak chu furnace-ah horizontal-in a lum a, chu chuan workpiece chu a ti lum vek a, chutah chuan circulating fan-ah chuan rear suction port kaltlangin a circulate leh stir vek a ni.
Deflector design a ni a, a design pawh a tha hle.
Volute hian fan performance-ah nghawng lian tak a nei a, volute hi paih a nih chuan fan performance chu 50% aia tam a tlahniam dawn a ni. Hot air box furnace hian double circulation mode a hmang a, fan chu furnace body hnung lamah dah a ni a, a sir lehlamah circulating air duct pahnih a awm a, a hnunglam volute-ah chuan kawng pahnih-way air outlet a awm bawk.
Hot air cavity-ah chuan hmun tlem avangin volute-a expansion section chu a tawi zawk a, outlet area a lian a, airflow pressure hloh a tam zawk bawk. Volute design-naah chuan deflector shape chu a dik tawk taka diffuse turin a bei tur a ni a, deflectors zat chu 4~8 pieces a ni tur a ni a, deflector installation angle chu impeller shape leh flow rate size a zirin a hriat tur a ni. Volute zau zawng hi impeller a khawih loh nan an design a ni.